Datasheet 搜索 > Schneider Electric(施耐德) > LT3SE00M Datasheet 文档
LT3SE00M
来自 AiPCBA

LT3SE00M 数据手册

Schneider Electric(施耐德)
8 页 / 0.1 MByte

LT3SE00 数据手册

Schneider Electric(施耐德)
Schneider Electric LT3-S RangeCan be used with all motors equipped with PTC thermistor probes. It monitors windings temperature and ensures that the rated operating value is not exceeded, therefore guarding against faults which are often the cause of premature ageing. They can also be used to monitor surface temperature.Automatic or manual reset Remote reset Fault storage with the supply switched off Fault indication Test function Comparison Guide --- Model Type | Reset Detail LT3SE00F, LT3SE00M | Automatic reset without thermistor, short-circuit detection (without fault memory) LT3SA00M, LT3SA00ED, LT3SA00MW | Automatic reset with thermistor, short-circuit detection (without fault memory) LT3SM00E, LT3SM00M | Manual reset and therrmistor, short-circuit protection (with fault memory) ### 电动机保护 - 继电器
Schneider Electric(施耐德)
Schneider Electric LT3-S RangeCan be used with all motors equipped with PTC thermistor probes. It monitors windings temperature and ensures that the rated operating value is not exceeded, therefore guarding against faults which are often the cause of premature ageing. They can also be used to monitor surface temperature.Automatic or manual reset Remote reset Fault storage with the supply switched off Fault indication Test function Comparison Guide --- Model Type | Reset Detail LT3SE00F, LT3SE00M | Automatic reset without thermistor, short-circuit detection (without fault memory) LT3SA00M, LT3SA00ED, LT3SA00MW | Automatic reset with thermistor, short-circuit detection (without fault memory) LT3SM00E, LT3SM00M | Manual reset and therrmistor, short-circuit protection (with fault memory) ### 电动机保护 - 继电器
Schneider Electric(施耐德)
Thermal protection relay for series LT3 S motorsProtection relay with probe, LT3 series, that permanently controls the temperature of machines that require protection (motors, alternators etc..). Operates via CTP thermistor probes. Automatic or manual reset. Faults displayed on the front panel of the device or remotely, except for version LT3 SE, which does not have this function. Fault detection if the probe circuit is accidentally cut off Three versions are available: LT3 SE: Control devices with no fault memory. LT3 SA: Automatic reset with thermistor short circuit detection device. Warning light on front panel. LT3 SM: Device with manual reset and thermistor short circuit detection. On the front panel there is a fault warning light and voltage indicator, and a test and reset button. Series | **LT3 SE** | **LT3 SA** | **LT3 SM** ---|---|---|--- Reset | - | Automatic | Manual / Automatic Fault indicator | - | On front panel and remotely | On front panel and remotely Fault test | without | without | LP on front panel Output: | 1 N/C | 1 N/O + 1 N/C | 1 N/O + 1 N/C Breaking capacity: | 6A / 250 V |   |   Operating temperature: | -25 → +60 °C |   |   **Stock no.** | **Voltage** | **Output** ---|---|--- 261-5660 | 115 Vac | 1 N/C 261-5676 | 230 Vac | 1 N/C 609-8069 | 24 Vdc | 1 N/C 261-5682 | 115 / 230 Vac | 1 N/O + 1 N/C 261-5698 | 24 Vdc / 48 DC | 1 N/O + 1 N/C 261-5711 | 24 → 230 Vac / dc | 2 C/O 261-5727 | 24 // 48 Vac | 1 N/O + 1 N/C 261-5733 | 115 / 230 Vac | 1 N/O + 1 N/C 609-8075 | 24 // 48 Vdc | 1 N/O + 1 N/C 609-8081 | 24 → 230 Vac / dc | 2 C/O ### 标准  IEC 60034-11, VDE 0660### 电动机保护 - 继电器
器件 Datasheet 文档搜索
数据库涵盖高达 72,405,303 个元件的数据手册,每天更新 5,000 多个 PDF 文件

关联型号